FLORIDATAP REPORTPUBLIC DATA • PLAIN ENGLISH

— 2025 PROVIDER REPORT

Okeechobee Utility Authority
water report

Start with the quick list. Amounts, limits and explanations are available farther down only if you want them.

SUBSTANCES REPORTED
  • Lead — current 2026 warning
  • Chlorine and chloramines
  • Haloacetic acids (HAA5)
  • Total trihalomethanes (TTHM)
  • Sodium
  • Nitrate as nitrogen
  • Nitrite as nitrogen
  • Turbidity
See amounts and explanations ↓
YOUR PROVIDER WATER SNAPSHOT● Verified official source
8REPORTED

Official 2025 annual report, plus OUA’s August 2026 lead action-level warning

The 2025 report listed no violations; a separate 2026 lead action-level exceedance remains under investigation

Okeechobee Utility Authority
“8 reported substances translated into plain English below.”

— QUICK WATER SUMMARY

What your water provider reported.

OUA treats water drawn from Lake Okeechobee using coagulation, filtration, ozonation and chloramines. Its 2025 annual report listed no violations in the reported tables. In August 2026, however, OUA issued a separate drinking-water warning after nine of 70 tap samples exceeded the lead action level. That newer warning matters more for the current lead status and does not mean every OUA customer has lead at the tap.

Start with the simple list below. Open See details to see whether the comparison is a legal limit, a health benchmark or another value used in the official report.

UTILITY REPORTDescribes the public system

Useful for source water, treatment and provider-wide monitoring.

PROPERTY TESTMeasures one address

Needed when the concern involves a building, service line, private well or exact tap.

IMPORTANTOne does not replace the other

A compliant utility report cannot rule out a plumbing issue inside one property.

Why can a legal water limit change? See what “safe” and “compliant” actually mean →

01Lead — current 2026 warningLead usually enters water through service lines, fixtures or household plumbing. The nine results do not establish the level at every OUA property.PROVIDER RESULT9 of 70 sampled taps exceeded 15 ppbSee details
REPORT COMPARISON VALUE15 ppb action level; utility action is required when more than 10% of sampled taps exceed it

Legal limits are enforceable. Health benchmarks and goals may be non-enforceable comparison values.

REPORT STATUSAction level exceeded in June–July 2026 sampling
TREATMENT CONTEXTCertified point-of-use RO or contaminant-specific filtration is commonly evaluated.
02Chlorine and chloraminesDisinfectants used to control microbes. OUA temporarily used free chlorine during April 2025 as routine distribution maintenance.PROVIDER RESULT2.1 ppm; range 0.2–3.5See details
REPORT COMPARISON VALUE4 ppm MRDL

Legal limits are enforceable. Health benchmarks and goals may be non-enforceable comparison values.

REPORT STATUSNo violation reported
TREATMENT CONTEXTWhole-home activated carbon is commonly evaluated.
03Haloacetic acids (HAA5)A byproduct created during drinking-water disinfection.PROVIDER RESULT16.50 ppb; range 2.2–19.6See details
REPORT COMPARISON VALUE60 ppb

Legal limits are enforceable. Health benchmarks and goals may be non-enforceable comparison values.

REPORT STATUSNo violation reported
TREATMENT CONTEXTWhole-home activated carbon is commonly evaluated.
04Total trihalomethanes (TTHM)A byproduct created during drinking-water disinfection.PROVIDER RESULT19.49 ppb; range 10.3–33.3See details
REPORT COMPARISON VALUE80 ppb

Legal limits are enforceable. Health benchmarks and goals may be non-enforceable comparison values.

REPORT STATUSNo violation reported
TREATMENT CONTEXTWhole-home activated carbon is commonly evaluated.
05SodiumCan reflect source-water conditions, saltwater influence and natural soil conditions.PROVIDER RESULT44 ppmSee details
REPORT COMPARISON VALUE160 ppm Florida standard

Legal limits are enforceable. Health benchmarks and goals may be non-enforceable comparison values.

REPORT STATUSNo violation reported
TREATMENT CONTEXTPoint-of-use reverse osmosis is commonly evaluated.
06Nitrate as nitrogenCan come from fertilizer runoff, septic systems, sewage and natural deposits.PROVIDER RESULT0.61 ppm; range 0.10–0.61See details
REPORT COMPARISON VALUE10 ppm

Legal limits are enforceable. Health benchmarks and goals may be non-enforceable comparison values.

REPORT STATUSNo violation reported
TREATMENT CONTEXTPoint-of-use reverse osmosis is commonly evaluated.
Hardness and TDS can vary from street to street.

A provider report cannot tell us the exact levels at your tap. We need to test your home to give you an accurate measurement.

Get my exact measurements →

*Provider reports describe the public distribution system—not the water at a specific home. Actual results vary by service address, plumbing, seasonal utility conditions and system configuration. A softener does not necessarily reduce TDS. Address-specific testing is required before treatment is recommended.

— YOUR LOCAL WATER HUB

What would you like to check next?

Stay with information for Okeechobee County. Choose one clear next step.

— FLORIDA TAP WATER NEWS & ANSWERS

Important Florida tap water news. Clear everyday answers.

Local developments, treatment changes and practical explanations built from official sources.

INTERACTIVE WATER-PROBLEM CHECKERDoes your water look, smell or taste different?

Choose what you are noticing and get common causes, a safe first check and guidance on when to call the utility.

Check my water symptom →
View all Florida Tap Water News →

— GET ADDRESS-SPECIFIC HELP

Want help with
your home’s water?

Public reports cannot measure your individual tap. Tell us where you live and Florida Tap Report will connect you with a water professional who serves your area.

Florida Premier directly serves Fort Lauderdale, Palm Beach County, Martin County, St. Lucie County and Tallahassee. Elsewhere in Florida, we will confirm a qualified local provider before connecting you.

  • ✓ Florida-wide request matching
  • ✓ Provider identity disclosed
  • ✓ No purchase obligation
START

Request a call from Florida Premier

Choose a preferred two-hour visit window in the form. This does not automatically book an appointment; Florida Premier confirms availability by call or text.

  1. 1Request a windowShare the address, water concern, preferred date and two-hour window.
  2. 2We review availabilityFlorida Premier checks service coverage and the team schedule.
  3. 3We confirm the visitThe appointment is set only after confirmation by call or text.
Preparing the secure request form—it loads as you approach it.
Prefer to speak with someone?Call 888-561-8736We can take the same request by phone.Prefer to text?Text 888-561-8736Send your community and what you notice about your water.Request reference: preparing🔒 Florida Tap Report and Florida Premier have common ownership. Florida Premier currently fulfills requests in Fort Lauderdale, Tallahassee and throughout Palm Beach, Martin and St. Lucie counties. Elsewhere in Florida, any provider relationship will be disclosed before service.